Fires & Heaters
Wetback Installation and Repairs in Auckland
Your wood burner can heat the water as well as the lounge. Or maybe the wetback you have is banging, steaming or barely warm. Taylor Plumbing installs, repairs, replaces and removes wetbacks across Auckland and the islands, on low pressure and mains pressure cylinders.
Our certifying plumber does the copper, the vent, the valves and the consent. Wetback boiling in the middle of the night? We answer 24/7.
Get help with wetbacks

Master Plumbers Member

Site Safe Member

Certifying Plumber, Gasfitter and Drainlayer
Google Rated 4.9
Get help with wetbacks
Overview & Answer
Can I get a wetback fitted in Auckland?
Yes, if your burner is built to take a water jacket and the cylinder can sit close to the fire. Our certifying plumber runs copper from the jacket to a vented cylinder, fits a tempering valve and gets the building consent. It pays off best when the fire burns every day through winter.
Hot water rises out of the jacket into the cylinder while cooler water sinks back to the fire, so most wetbacks need no pump. When the fire sits cold, including all summer, the element takes over.
Wetback banging, boiling or out of water? Do this first
Banging, rumbling or steam
Put no more wood on and let the fire burn down. Leave the water on, because the jacket needs water through it while there is any heat in the firebox. Keep clear of the roof vent and any relief valve outlet, then ring us.
Water off or pump down
Do not light the fire while the mains are off, the header tank is empty or a power cut has stopped your tank pump. A dry jacket can flash to steam.
Leak at the fire or cylinder
Let the fire go right out before anyone shuts a valve. After a leak, leave it unlit until a plumber has refilled and checked the system. Stay away from the cylinder's wiring if water is near it.
Someone burnt or the fire spreading
Get everyone outside and call 111.
Scope & Inclusions
- New wetbacks on wood burners
- Low pressure and mains pressure wetback cylinders
- Pumped wetback systems
- Kettling, boiling and banging
- Vent pipes, relief and expansion valves
- Wetback removal and capping
Need something close to this?
Swapping the wood burner for a gas fire?
Gas FiresWant the sun covering your hot water in summer?
Solar Hot WaterShowers scalding, or swinging hot and cold?
Tempering ValvesRadiators or a boiler playing up?
Heating Repairs
Signs & Symptoms
When a wetback needs a plumber
Ring us if any of these sound familiar.
Rumbling or knocking with the fire going
Water is boiling in hot spots. Scale inside the jacket, or a pipe that does not climb enough on its way to the cylinder, is the usual cause.
Steam or water out of the roof vent
An open vented cylinder dumps heat this way when it runs too hot. Once in a while is fine. Every time you light the fire is not.
Relief valve running
On mains pressure coil cylinders these valves open more often than on plain electric ones and wear out sooner. Nonstop running means a valve or setting needs looking at.
Roaring fire, lukewarm water
The water is not circulating. Air in the loop, a sagging run, pipe that is too small or a cylinder too far away will all do it.
Water around the hearth or cylinder
A jacket, joint or cylinder is leaking. Keep the fire out until it is repaired.
Taps running scalding hot
A fire has no thermostat, so the tempering valve is the only thing holding the bathroom down to a safe heat.
Cylinders & Setups
Three ways to plumb a wetback
The fire side stays vented to open air in every one. What changes is how the heat gets to your taps.
Low pressure, open vented
The simplest and cheapest: a copper cylinder fed from a header tank, with an open pipe through the roof in place of pressure valves. Nothing to pump or wear out. Showers are gentler, and the cylinder has to sit near the fire and higher than it.
Mains pressure, thermosiphon coil
The usual choice for a new install. Fire water rises through a coil inside a stainless cylinder and hands its heat to mains pressure water, so showers stay strong without a pump. Its relief and expansion valves get a workout and need changing more often.
Mains pressure, pumped coil
A high temperature pump drives fire water to the coil, so the cylinder can go where it fits instead of right beside the fire. You gain some control over the heat and take on a pump to maintain.
Proof & Promise
Why ring Taylor about wetbacks
Certifying plumber in house
Level says a wetback must be done by a certifying plumber, or someone working under one. Ours signs the work off, and home work carries the Master Plumbers Guarantee: 12 months, up to $20,000 incl GST. We also back our labour with a lifetime workmanship guarantee, and parts keep the maker's warranty.
All three setups
Low pressure, thermosiphon coil or pumped, on any burner built to take a jacket. We choose what suits the house, not whatever is on the shelf.
Consent done for you
Plumbing schematic, cylinder position, producer statement and the inspection booking go to council together with the burner details.
Tempering that keeps your flow
We match the valve to your water pressure, so a low pressure shower does not drop to a dribble once the wetback is tempered.
A real person 24/7
Cylinder thumping or the vent pouring steam late at night? Ring any hour and talk to someone who knows wetbacks.
A written price first
Jacket, cylinder, copper, vent, valves, consent, electrician and GST set out before work starts. Extras wait for your yes.
Heat & Circulation
Fire, water and a copper loop
A wetback is a water jacket at the back or side of the firebox, joined to the cylinder by two copper pipes. Hot water climbs the flow pipe, cooler water drops down the return, and that loop keeps turning while the fire burns.
It only works if the pipes rise steadily with no dips. BRANZ Level recommends 25 mm copper, and burner manuals want the return to rise at least 1 in 12. Pulse valves or a pump let the cylinder sit further off.
Jackets put roughly 1.5 to 4 kW into the water. That heat comes out of the room, so the lounge runs a little cooler.
Safety & Pressure
Why wetbacks boil and bang
Nothing turns a fire down when the cylinder is full of hot water. That is why the wetback side must be vented to open air, and why MBIE says a wetback cannot be connected directly to a mains pressure supply.
Kettling is water flashing to steam in a hot spot. Scale and poor flow cause it: lime coats the jacket, or a sagging pipe stalls the loop. Level says wetbacks do not suit water very high in lime.
In 2012 a Papamoa wetback heater exploded after its water was turned off for a leak and never drained. Steam, banging or a leak is a reason to let the fire die, never to shut the water off with the fire still going.
Rules & Approvals
Consent, clean air and tempering
Plan on a building consent for any new wetback, including one added to a burner you already have. District councils issue consents for heating appliances, and they want a plumbing schematic and the cylinder position along with the burner details.
On a section under 2 ha, the burner has to be on the Ministry for the Environment's authorised list, and models with a wetback are no exception. A jacket cools the fire and lifts its emissions, so the burner must pass with the jacket fitted.
Fire heated water has to be tempered before it reaches a bathroom tap. Choose the wrong valve on a low pressure system and the shower can fade to a trickle: in a 2018 Masterton case, MBIE ruled a wetback job failed the Building Code at 1.4 litres a minute.
Retrofits & Removals
Adding, swapping or taking one out
Not every burner takes a jacket, and fitting one the maker never approved can void the burner's emissions approval. We check the model before anything else. If it cannot take one, the choice is a new burner or no wetback.
A worn out wetback cylinder can be replaced without consent when the new one is a comparable open vented cylinder, in the same spot, on the same pipework. That comes from Schedule 1 of the Building Act. Moving it, new pipe runs or a switch to mains pressure means consent first.
Taking the fire out? We drain the loop, cut and cap the copper, and leave the cylinder heating on its element. If it is old, that is the time to talk about a mains pressure or heat pump cylinder.
Value & Payback
Who a wetback pays off for
Consumer NZ puts it plainly: if the fire is not lit every day, a wetback is unlikely to earn its keep. It suits:
- Rural homes and lifestyle blocks with their own firewood
- People home most of the day, like retirees and farmers
- New builds and big renovations, where the cylinder can go right beside the fire
- Homes with solar hot water to carry the summer months
Fire only on weekends, or the cylinder at the far end of the house? A heat pump water heater may be the better spend, and we will say so.
Process & Steps
From first call to hot water off the fire
01
Tell us about the fire
Burner make and model, where the cylinder sits and how strong your showers are. Photos help.
02
Site check
We confirm the burner takes a jacket, measure the pipe route and vent, and look at your water supply.
03
Quote and consent
A written price, then we draw the plumbing schematic and lodge the consent with the burner details.
04
Install, fill and test
Loop, vent, valves and tempering in, the system filled and run with a fire lit, then inspection and paperwork.
Costs & Quotes
How wetback work is priced
Repairs and valve work go on time and parts, and we explain how that adds up before we head out. New installs, cylinder swaps and removals get a fixed written quote once we have seen the fire and the cylinder.
What moves it: the burner, jacket size, cylinder type and size, pipe length and height, roof vent, valves, consent and inspection fees, any electrician, travel and GST.
Request a quoteAuckland & Islands
Wetbacks across Auckland
The vans run out of Wiri to every zone, from rural Rodney and Franklin blocks to City & Isthmus villas, and to the islands by arrangement.
Your wetback consent goes to Auckland Council. Its fixed fee for a solid fuel heater with a wetback is $327 plus a $195 inspection deposit, as listed on the council's building control fees page in November 2026. That fee is the council's, separate from our price.
On a site under 2 ha, any burner installed after 1 September 2005, wetback model included, must meet the national limits of 1.5 g/kg and 65% efficiency. Gas fires can go in anywhere in Auckland.
Auckland Council building feesCustomers & Properties
Who calls us about wetbacks
Rural homes and lifestyle blocks
Firewood on hand, tank or bore water and the burner going all winter.
Baches and holiday homes
Fire on when you are up, element the rest of the time. We check the loop before winter.
Builders and renovators
Burner and cylinder placed together at the design stage, before linings go up.
Landlords and property managers
Wetback cylinders, valves and tempering kept in order.
Related & Similar
Related services
Other work on the same fire or cylinder.
Cylinder Replacement
When the cylinder is as tired as the fire.
Leaking Hot Water Cylinder
Water pooling under or around the cylinder.
Wood Burners
Choosing and fitting the fire itself.
Heat Pump Hot Water
Cheap hot water on the days the fire is out.
Questions & Answers
Wetback questions
How much does it cost to install a wetback in Auckland?
We quote after seeing your fire, cylinder and house. A burner that already takes a jacket, with the cylinder just behind the wall, is the easy end. A new burner, a new mains pressure cylinder or a long pipe run is the dear end. Consumer NZ calls wetbacks expensive to install.
Will a wetback lower my power bill?
Yes, through winter, if the fire runs every day. The saving stops when the fire does, so the cylinder still needs its element for summer. Consumer NZ says the sums work best for people home most of the day, not households out at work.
Can I have mains pressure hot water with a wetback?
Yes. The wetback itself must stay vented, so it cannot connect straight to the mains, but it can heat a coil inside a mains pressure cylinder. The catch is relief and expansion valves that work harder and need replacing more often than on a plain electric cylinder.
Why does my wetback bang or rumble?
That is kettling, water flashing to steam in hot spots. Usual causes are lime or scale inside the jacket, a pipe that dips or climbs too little, air in the loop, or a cylinder already at full heat. Let the fire burn down and get it checked, because the noise means the system is running too hot.
Is it dangerous if my wetback boils?
Yes, if the vent is blocked or the jacket runs dry. A vented system lets steam escape up the roof pipe, but a blocked vent, a dry jacket or water trapped behind a closed valve can build pressure fast. Stop feeding the fire, leave the water on and call us. Regular boiling also cooks the cylinder, and MBIE warns high temperatures can damage them.
Can I use the fire when the water is turned off?
No. Burner makers say water must always be available to the wetback while the fire is going. Mains off for repairs, an empty header tank or a tank pump stopped by a power cut all count. Leave the fire unlit until the water is back on and the cylinder has refilled.
Does a wetback need a building consent in Auckland?
Yes. BRANZ Level says a building consent is needed to install a wetback, and adding one to an existing burner is still an install. In Auckland it goes to Auckland Council, and a wetback always gets an inspection. We put the application together and book the inspection.
Can a wetback be added to my existing wood burner in Auckland?
Only if the burner was designed for one. Makers sell jackets for certain models, and fitting anything else can void the emissions approval. On a section under 2 ha the burner must stay compliant with the jacket in, and some do not. Send us the make and model and we check before you spend a cent.
Can I replace a wetback cylinder without consent?
Yes, when the new one is a comparable open vented cylinder fixed in the same place on the same pipework. Schedule 1 of the Building Act exempts that swap. Moving the cylinder, new pipe runs or a change to a mains pressure coil cylinder fall outside it, so consent comes first. We check which applies before we quote.
Do I need a tempering valve with a wetback?
Yes, for bathroom taps. Fire heated water has no thermostat, and the Building Code does not allow untempered water from an uncontrolled heat source like a wetback to reach them. BRANZ calls tempering every tap on a wetback system good practice. We fit a tempering valve rated for the heat and suited to your pressure.
Can you take a wetback out when the fire goes?
Yes. We drain the loop, take out or cap the copper at the cylinder and the vent, and make sure the cylinder heats properly on its element alone. If it is an old low pressure cylinder, swapping it for mains pressure or a heat pump at the same visit saves a second call out.
Will a wetback work on tank water?
Yes, with the right setup. A tank below the house feeding it by pump leaves the wetback short of water whenever the pump stops. A header tank in the roof, or a different wetback type, gets around that. Have hard bore water tested first, since Level says wetbacks do not suit water very high in lime.
How close must the cylinder be to the fire?
As close as you can get it, and higher than the fire for any system without a pump. The further the hot water travels, the more heat it loses on the way. If the cylinder has to sit across the house, a pumped coil cylinder or pulse valves can make it work.
Is my wood burner and wetback legal to use in urban Auckland?
If it went in after 1 September 2005 on a site under 2 ha, it must meet the national limits of 1.5 g/kg and 65% efficiency and be an authorised model, or it is illegal to use. Send us the make and model from the plate and we check it against the authorised list for you.
Do you come out after hours for wetback problems?
Yes. A person answers 24/7, and a boiling or leaking wetback goes to the front of the queue. Follow the safety steps on this page first, then ring us and tell us what you can hear and see.
Want hot water from your fire?
Send us the burner model and where the cylinder sits. We will tell you what fits.