Testing & Inspections

Tempering Valve Replacement and Testing in Auckland

Our plumbers test, service and replace tempering valves and thermostatic mixing valves across Auckland, in homes, rentals, apartments, schools, early learning centres and care homes. A shower burning hot one minute and tepid the next, or a bathroom tap that scalds, is often the small brass valve near your cylinder.

A tap running dangerously hot is a safety fault, and we answer 24/7. You are told an arrival time for your address before a plumber sets off. If someone has been burnt, deal with the burn first using the steps on this page.

  • Master Plumbers member logo

    Master Plumbers Member

  • Site Safe member logo

    Site Safe Member

  • Certifying Plumber, Certifying Gasfitter and Certifying Drainlayer

    Certifying Plumber, Gasfitter and Drainlayer

  • Google logo

    Google Rated 4.9

Get help with tempering valves

Overview & Answer

What does a tempering valve do?

A tempering valve mixes cold water into the hot leaving your cylinder, so bathroom taps and showers get water at a safe set temperature, usually 50°C or lower. The cylinder itself stays at 60°C or more to stop legionella growing. When the valve fails, you get scalding water, wild temperature swings or lukewarm showers.

A thermostatic mixing valve, or TMV, does the same job with tighter control and cuts the hot if the cold supply fails, which is why schools, hospitals and care homes use them. Whichever you have, only a licensed plumber may fit or adjust it.

Tap running scalding hot? Do this first

  1. Someone has been scalded

    Hold the burn under cool running water for 20 minutes. No ice, oils or creams. Take off clothing near the burn unless it is stuck. Call 111 if the burn is on the face, hands or genitals, or bigger than a child's forearm.

  2. Stop it happening again

    Run the cold first and turn the hot off first. Keep children out of the bathroom unless an adult is there, and test bath water before anyone gets in.

  3. Leave the cylinder setting alone

    Turning the cylinder down below 60°C lets legionella grow, and the thermostat is electrician's work anyway. The fix belongs at the valve.

  4. Water spraying from the valve

    Switch the cylinder off at its isolating switch, then close the cold valve feeding the cylinder. Keep clear of any power points that are wet.

Call 09 873 6671

Scope & Inclusions

  • Tempering valve replacement
  • Tempering valve testing and servicing
  • Thermostatic mixing valves (TMVs)
  • Yearly TMV checks with written records
  • Scalding taps and swinging showers
  • New bathrooms set to the 50°C limit

Need something else?

Signs & Symptoms

Signs your tempering valve is failing

Most valves give some warning before they quit. These are the calls we get.

  • Bathroom tap too hot to hold

    If a basin or shower runs hotter than your hand can stand, the valve has failed open or been knocked off its setting.

  • Hot one minute, cold the next

    Swings mid shower point to a worn or scaled valve, or hot and cold pressures that do not match.

  • Hot water seems to run out early

    A valve stuck towards cold makes showers tepid while the tank is still full, so it feels like the hot has gone.

  • Weak flow on the hot side only

    A blocked strainer or a melted non return valve chokes the hot supply to the bathroom.

  • Dripping or crusting at the valve

    Water weeping from the body or unions, or white scale building up, means the valve is wearing out.

  • The setting does nothing

    If turning the adjuster changes nothing, the insides have seized. These valves cannot be rebuilt.

Valves & Options

Four ways to keep bathroom water safe

Every one of them mixes or limits the heat. Where it sits and how tightly it holds the temperature is what changes.

  • Tempering valve

    One valve on the hot pipe near the cylinder feeds every bathroom. It suits homes, rentals and most new bathrooms.

  • Thermostatic mixing valve

    Usually fitted close to the basin or shower it serves, holding a set temperature within a couple of degrees.

  • Thermostatic tap or mixer

    The mixing happens at the outlet itself. Good for one shower that needs its own lower setting.

    Shower Repairs
  • Temperature limited heater

    Some continuous flow heaters are locked at 50°C and need no extra valve. Set one higher and a valve or locked controller must go in.

    Gas Hot Water

Proof & Promise

Why call Taylor about tempering valves?

  • A certifying plumber on every job

    We are Master Plumbers members. Our plumbers set and test every valve we touch, and our in house certifying plumber signs it off. On a house, the Master Plumbers Guarantee stands behind our workmanship for 12 months, capped at $20,000 including GST. Our labour also has a lifetime workmanship guarantee, and parts keep the maker's warranty.

  • TMV testing for schools and care homes

    We test TMVs at schools, early learning centres, rest homes and clinics, set each to its limit and leave a written record for your next audit or licensing check.

  • 24/7 for scalding water

    Water hot enough to burn is a safety fault, so we answer day or night and talk you through making it safe. Ring or WhatsApp any hour, and a scald fault gets an arrival time for your address before a plumber leaves.

  • Electrician in house

    When the cylinder thermostat is the real fault, our in house electrician sorts that side, so you deal with one team.

  • Measured, not guessed

    We read the temperature at the tap before and after, and write the reading and date on the valve tag and your invoice.

  • Any system, any brand

    Electric, gas, heat pump, solar or wetback, mains or low pressure, whatever the brand of valve.

Rules & Regulations

What the Building Code asks for

Since 2 November 2024, new basins, baths, showers and bidets in a house must get water no hotter than 50°C under the Building Code's acceptable solution. Before that the limit was 55°C. Older fixtures do not have to change, so plenty of Auckland homes still run hotter.

Schools, hospitals and care homes keep a 45°C limit. Early learning centres go lower again, because Ministry of Education licensing caps taps children can reach on their own at 40°C. Kitchen sinks and laundry tubs are not treated as personal hygiene fixtures, so they can run hotter.

Water heated by a wetback or solar panels must never reach a tap untempered. Systems put in before 1992 seldom had any temperature control at all.

Legionella & Temperature

Why the cylinder stays at 60°C

Legionella bacteria breed in lukewarm water. Public health services tell households to keep the cylinder at 60°C or more, and BRANZ says stored water needs to reach 60°C at least once a day.

People catch Legionnaires' disease by breathing in fine spray, like shower mist, not by drinking the water. So the tank stays hot and the valve does the cooling on the way to the bathroom.

Scalding & Time

How fast hot water burns

MBIE's burn table shows why a few degrees matter. At 60°C a child can suffer a full thickness burn in about 1.5 seconds. At 55°C it takes about 8 seconds, and at 50°C closer to two minutes, which is time to get out of the water.

Safekids Aotearoa counted 283 children admitted to hospital with hot tap water burns from 2009 to 2018, and 239 of them were under five. That is about one in nine of all child burn admissions.

Pressure & Valves

The wrong valve can kill your shower

Plenty of Auckland villas and bungalows still have a low pressure cylinder fed from a header tank. Put a mains pressure valve on one of those and the shower can drop to a dribble. MBIE ruled on a Masterton house where a new valve cut the shower to 1.4 litres a minute, and the council's code compliance certificate was reversed.

We match the valve to the pressure you actually have. Makers say uneven hot and cold pressures upset the mix, so where they differ we balance them first, often with a pressure limiting valve.

Tanks & Bores

Hard water and grit wear valves out

Grit from roof tanks, scale from bores and Waiuku's moderately hard mains water clog the fine strainers inside a valve. Valve makers ask for more frequent testing where water quality is poor, and a Y strainer on the supply catches the worst of it.

Wetbacks and solar panels can push a tank well past 60°C. BRANZ calls it good practice to temper every tap on those systems, so we fit a valve rated for the higher heat.

Process & Steps

From scalding tap to signed off

  1. 01

    Tell us what is happening

    Which taps, how hot or cold, and whether you are on mains or low pressure. A photo of the valve and the cylinder label helps.

  2. 02

    Test at the tap

    We measure the water at the cylinder and at each tempered outlet, then check strainers, non return valves and pressures.

  3. 03

    Repair or replace

    If cleaning and resetting fixes it, that is all we do. A seized or worn valve gets replaced once you have said yes to the price.

  4. 04

    Set, prove and record

    We set the valve to its limit, shut off the cold to prove the safety cut works, then tag it with the date and reading.

Costs & Quotes

How tempering valve work is priced

There is no fixed price here because the valve, the access and the system all change the job. You get the cost in writing before we start.

A replacement quote lists the valve matched to your pressure and temperature, isolating valves and strainers where they are missing, labour, the temperature test and record, travel and GST.

It costs more when the valve is buried in a wall or ceiling, when old pipework needs changing to take a modern valve, when the supplies need a pressure limiting valve, or when outlets each need their own valve.

For schools, care homes and businesses we quote TMV testing per site, listing every valve and where it is, so you can budget for it each year.

Request a quote

Auckland & Islands

Tempering valves around Auckland

Around Auckland we see every kind of setup: header tank cylinders in isthmus villas, mains pressure in new subdivisions, central hot water plant in apartment towers, wetbacks on rural blocks, and tank or bore water past the Watercare network. Each one needs a different valve.

Our vans leave Wiri for every zone, from City & Isthmus and Takapuna & Albany to Manukau & Papakura and the islands. Schools and care homes can book their yearly TMV round together, with any rural or island travel set out in the quote.

MoE hot water tap rule

Customers & Properties

Homes, landlords, schools and care homes

  • Homeowners

    New bathroom, new cylinder or a tap that catches the kids out: we set it right and show you how to check it yourself.

  • Landlords and property managers

    We sort scalding or tepid complaints quickly, deal with the tenant directly and send you the readings.

  • Early learning centres and schools

    We set and check the valves on children's taps and give you a record to show at licensing visits.

  • Rest homes and clinics

    A Ministry of Health audit marked one rest home down for keeping no record of hot water checks. You get the test readings for your records.

Related & Similar

Related hot water and testing services

Cylinder faults, shower problems and other safety checks each have their own page.

View all plumbing services

Questions & Answers

Tempering valve questions

What is the legal hot water temperature in NZ?

For new bathroom fixtures in a home, 50°C at the tap, under the Building Code acceptable solution in force since 2 November 2024. Schools, hospitals and care homes have a 45°C limit, and early learning centres 40°C at taps children use on their own. Stored water must be kept at 60°C or above.

Is a tempering valve compulsory?

It is for new bathroom fixtures fed by a heater that is not already limited to 50°C. Bathrooms fitted before 2 November 2024 do not have to be upgraded, and MBIE has ruled that changing a wetback did not force a valve onto existing taps. Most cylinder makers expect one on a new install anyway.

How long does a tempering valve last on Auckland water?

There is no set life, because water quality decides it. On Watercare mains a valve can run for years, while gritty tank water, scaly bore water or Waiuku's harder supply can finish one much sooner. Valve warranties typically run five years from manufacture. A valve that fails its yearly temperature check gets replaced.

How often should a tempering valve be checked?

Once a year. Valve makers ask for a yearly check by a plumber, and sooner where water quality is poor. We measure the water at the outlet it was set on and compare it with the setting. Drift of more than about 2°C means the valve needs work.

Do TMVs need yearly testing and an IQP?

They need regular testing, but no IQP. TMVs are not a specified system, so they are not on a building warrant of fitness. The acceptable solution cites AS 4032.3 for testing and maintenance, and makers ask for yearly checks. Schools, early learning centres and care homes should keep written results.

What is the difference between a tempering valve and a TMV?

A TMV holds the temperature more precisely and is built for the 45°C limit, while a tempering valve is the simpler mixer used for 50°C. MBIE accepts tempering valves where 50°C applies and TMVs where 45°C applies. That is why homes usually have one and schools or care homes the other.

Can I adjust my tempering valve myself?

No. MBIE says only a licensed plumber may install or adjust one, and the makers agree. Wind it up and you risk scalds. Set it too close to the cylinder temperature and its safety cut stops working. Tell us what feels wrong and we reset it with a thermometer.

Why does my shower swing between hot and cold?

Usually a tempering valve that is worn, scaled or fed by uneven pressures. A tired mixer cartridge, a pump cycling on tank water or a toilet flushing nearby can cause it too. If every shower swings, suspect the valve. If only one does, the mixer is the better bet.

Where is my tempering valve?

Usually on the hot pipe near the cylinder, in the hot water cupboard or roof space. Look for a brass body with three pipe connections and a plastic cap. Some homes have one under each basin instead, and older houses may have none.

Can a tempering valve cause no hot water?

Yes. A melted non return valve or a blocked strainer can stop hot water reaching the bathroom even with a full, hot cylinder. Try the kitchen tap, which is often not tempered. If it runs hot and the bathroom does not, the valve is the likely culprit.

Can a tempering valve be repaired?

Only partly. Strainers and non return valves can often be cleaned through the unions, but the valve body cannot be rebuilt. Valve makers say a failed valve is replaced, not serviced. We clean first when that fixes it and replace it when the temperature still will not hold.

Does a tempering valve work on a low pressure system?

Yes, if it is a valve made for low pressure. Check before anyone fits a standard valve to a header tank system, because the wrong one can cut your shower to a trickle. We choose the valve after measuring both supplies.

Do I need a building consent to replace a tempering valve?

Usually not. MBIE lists repair, maintenance and replacement of sanitary plumbing as exempt work when an authorised person does it, meaning a certifying plumber or someone they supervise. The work still has to be done right, and you can check any plumber on the PGDB public register.

How much does it cost to replace a tempering valve in Auckland?

It depends on where the valve sits and what feeds it, and we give you a written price with GST shown before any work starts. A straight swap beside the cylinder is the simple end of the scale. A valve hidden in a wall, a low pressure model or extra pipe changes add to it.

Do you test TMVs for Auckland schools, early learning centres and rest homes?

Yes. We test each valve at the outlet it serves, record the reading against the limit that applies, and service or replace any that drift. Tell us how many outlets the site has and we book the whole round together, with a written record for your audit.

Get your hot water back to a safe temperature

Tell us which taps are too hot, too cold or swinging. We test, fix and record it, in one visit wherever we can.

Get help with tempering valves

Get my quoteGet a quote